Short Circuit And Earth Fault Indicator

Business Type
Country
China
Category
Price
$50/set (Get Latest Price)

Quick Details

Brand Name: SNOVA
Model Number: SNV-EKL3,4
Place of Origin: CHINA
MOQ: 6 sets
Color: Black
Certificate: ISO9100
Usage: power system , a variety of ring network cabinets, high-voltage
Packaging: with carton
Capacity: 5000 sets/ month

Product Detail

Grounding Fault and Short Circuit Fault Indicator\r\nGeneral:\r\nThe Short Circuit and Earth Fault Indicator is an instrument for detecting short circuit and earth fault. This indicator is used in each loop of medium voltage radial networks. In order to avoid serious failure happening to distribution power network, especially in the network where lots of ring main unit with load break switch were used, the upper level system must be tripped within the set time when short circuit or earth fault occurs in the lower level. When tripping and breaking happens, the whole network subjected to the upper level will be power off. The indicator can locate and indicate the fault section so that the operator can find and trip the fault section quickly according to the alarm signal; this will not only save a lot of working time, but also shorten the system interruption duration and range of power outage. \r\n \r\nStructure and Component: \r\nThe Short Circuit and Earth Fault Indicator consists of:\r\n3 pcs. short circuit sensors for each phase cable\r\n1 pc. earth fault sensor for three-phase cable\r\n1 pc. Indicating unit, which is connected with sensors by cables or optical fiber and is incorporated in a wholly sealed plastic housing to gather with the electronics for time reset and trip setting. \r\n \r\nFaults Indication:\r\nThe faults can be indicated as follows:\r\n Short circuit with one LED for each phase on the panel\r\n Earth fault-with one LED on the panel\r\n The fault status can be displayed on the panel or indicated remotely through remote sign contact.\r\n  \r\nFunction:\r\nThe sensors are used to detect the load current and earth current respectively. A threshold level electronic adjusts the trip level for earth fault and short circuit. When the current exceeds the pre-adjusted threshold level, an impulse is sent to the indicating unit,and then the respective LED is activated and starts to blink.\r\nMinimum pulse current adjustment: the indicating unit is equipped with a minimum impulse threshold current used to evaluate the pulse current from the sensor. If the pulse current is less than the threshold level, no fault will be indicated. And if the pulse current is higher than the threshold level, an earth fault or short circuit fault will be indicated.\r\nThe equipment has the function of inrush restraint, which avoids the wrong indication by the switching on/off operation.\r\nConnection terminal with a cover is to avoid short circuit and damage by dusts and dew. \r\n \r\nReset:\r\n1. Automatic time reset: A time element controls the indication and resets it after the preadjust time  (Values between 2~48h are optional at plan).\r\n2. Manual reset: Reset the indication by the TEST/RESET button on the panel (Press for RESET, press and remain 5 seconds for TEST)

Similar Products

Transformer

About our Company

Established
2004
Employess
101 - 200 People
Main Markets
North America, Eastern Europe, East Asia, South America, Southern Europe, South Asia, Oceania, Central America, Western Europe, Middle East
Export Ratio
41% - 50%
Products
Transformer

Regional Suppliers

Transformer in China

Contact Us

Zhuhai SNOVA Technology(Hongkong) Co., Ltd.

Ms. Betty Lucy

3021 mingzhu road

zhuhai GuangDong China

Send us a message