Access Control AC110 / 220V Electric Barrier Gate For Parking System

Business Type
Manufacturer
Country
China

Product Detail

Access Control AC110 / 220V Electric Barrier Gate For Parking System Advanced Features: 1)clutch key can be used to open the clutch when power off. 2)Fan cooling machine reduce the motor temperature by high frequency using, never get heat-protecting, unique temperature calefaction design for low temperature using, prevent freezing in cold weather. 3)Exactitude aluminium alloy die-casting motor base reduce the noise and joint abrasion to prolong the barrier gate working life. Model Selection and Differences Specifications - - - - Model | WST1211 | Working Temperature | -40+75 | Voltage | 220V10%, 110V10%, 50/60HZ | Rated power | 80W | Relative humidity | 90% | Remote control distance | 30m | Net weight | 48kgs | Speed | 1S,1.8S,3S, 6S | Max boom length | 6 meters | Motor Rotational speed | 1400rmp | Protection Degree | IP44 | - - - - Communication with customers 1)Q:Connected power and press open/close button but traffic barrier gate no action? - - - - A | Reason | Solution | 1 | Fuse blown | Check fuse and power in controller | 2 | Batteryof remote control powered off | Change a new one | 3 | External protection circuit break or at protecting status | Open the barrier door and click OPEN/CLOSE button on control box | 4 | Same frequency interference | Check photocell and loop detector | - - - - 2) Q:Connected power and press open/close button,traffic barrier gate will move but even when it is at right position, the motor still running and not stop? - - - - A | Reason | Solution | 1 | Limit switch | Adjust the horizontal/vertical limit switch to correct position | 2 | Main controller failure | Change a new one | - - - - 3)Q:Motor running but traffic barrier gate arm no action? - - - - A | Reason | Solution | 1 | Barrier arm at 45 position where is hard to move | Unlock clutch and manually rotate arm to horizontal or vertical position then try again | 2 | Tension of balancing spring not suitable | Adjust spring exactly | 3 | Low working voltage | Check the voltage and power | - - - - 4)Q:When opening/closing,traffic barrier gate arm cannot reach right position (90 vertical & 180 horizontal)? - - - - A. | Reason | Solution | 1 | Length adjustment of connecting rod not correct | Open barrier door and unlock clutch to check when arm at 90vertical position if the master rod covers slave one; when arm at 180horizontal position if master rod and slave one are in the same straight line | 2 | Nuts on the limit switch loose | Tighten the nuts when arm at 90vertical and 180horizontal | - - - - 1 pcs Gate Barrier 1 pcs arm boom (from 1m to 6m can customised) 1 pcs control panel(built inside) 2 pcs remote controllers 1 pcs manual book .
Ms. 84536531 84536531
Contact Us Contact Details

Similar Products

Access Control System

About our Company

Business Type
Manufacturer
Products
Access Control System

Regional Suppliers

Access Control System in China

Contact Us

Shenzhen Wonsun Machinery & Electrical Technology Co. Ltd

Ms. 84536531 84536531

China

Send us a message