50Hz / 60Hz 380V / 220V Military Uninterruptible Power Supply 30 Kva Online Ups

Business Type
Manufacturer
Country
China
Category

Product Detail



I3D30K 3/1 Phase 30Kva 380/220Vac On-line Low Frequency UPS RS232 USB SNMP Slot



Application Field
1. Computers
2. Home Appliance, such as Fans and lights
3. Office, like computers with Printers
4. Aeronaoutics & Astronautics
5. Electronic & Telecom
6. Army Technology
7. Securities System/ Monitoring / Alarm
8. Sensitive Electronic Equipment
9. Wind Power System
10. Production Equipment
11. Military
12. Medical Systems
13. Network
14. Instrumentation
15. Servers and so on


Specifications: 1 isolated transformer
2 ture online ups power system
3 IGBT and SPWM technologies
4 smart RS232 port


- - - -
Input voltage |
Rated voltage | 380VAC | Line voltage |
Phase | 3 + N +P E(protective earth) | |
Turn on voltage range | 380VAC25% | Line voltage |
Bypass voltage range | 220VAC25% | Phase voltage Could be adjusted by software. |
Bypass low loss | 165VAC |
Bypass low comeback | Low loss +10VAC |
Bypass high loss | 275VAC |
Bypass high comeback | High loss-10VAC |
Line low loss/comeback | (1655) VAC /(1805) VAC | |
Line high loss/comeback | (2755)VAC/(2605)VAC | |
Input frequency |
Rated frequency | 50Hz | Could be adjusted by software. |
Frequency low loss | (40~49)0.2Hz(default:46Hz) |
Frequency low comeback | Frequency low loss + 0.5Hz |
Frequency high loss | (51~60)0.2Hz(default:54Hz) |
Frequency high comeback | Frequency high loss - 0.5Hz |
Input power factor |
Input power factor | 0.7 | 220VAC,full R load |
Generator | Support generator input | Generator rating2*UPS rating |
Input current |
Rated current | 71A | |
Input protection |
Rated protection | 100A | |
Output |
Output power |
VA/watt | 30kVA/24kW | |
Rated voltage | 220VAC | Sine wave |
Phase | Single phase with ground | |
Voltage range | 200/208/220/230/240VAC | Could be adjusted by software. 10% derating for 208VAC/200VAC. |
Voltage regulation | 2% | |
Voltage distortion | 8 | Full RCD load |
3 | Full R load |
DC offset | 100mV | |
Transient response | 9 | R load 01000 |
6 | R load 2010020 |
Transient recovery | 60ms voltage recovery to 90% | Full RCD load |
Bypass output before turn-on | Yes | |
Crest ration | 3:1 | |
Output frequency range |
Line mode | 1.Same as input frequency(46Hz~54Hz) | |
2.50Hz(Input frequency>54Hz or Input frequency<46Hz) | |
Battery mode | (50+0.1) Hz | |
Slew rate | 1 Hz/Sec | |
Efficiency |
Line mode | > 88% | R load |
Battery mode | > 90% | R load |
Overload |
line mode/battery mode | Overload warning only | 105%5%load |
2Min,then transfer to bypass and alarm. | 105%5%<load125%5% |
30S,then transfer to bypass and alarm. | 125%5%<load150%5% |
0.5S,then transfer to bypass and alarm. | load>150%5% |
Automatically recovery | Yes | |
Short protection |
Line/battery mode | Cut off output and alarm after 3S | |
Transfer time |
Line to battery mode | 0mS | |
Battery to line mode | 0mS | |
Line to bypass mode | <1mS | |
Bypass to line mode | <1mS | |
Battery and charger |
Battery |
Rated voltage | 384VDC | |
Protection |
Low alarm voltage / comeback voltage | (361.6V4V)/ (377.6V4V) | |
Shutdown voltage | (320V4V)/ (336V4V) | |
Battery protection |
Overcharge protection | (475V4V) | |
Battery test |
Battery weak | Support | |
Battery fault | Support | |
Charger |
Output voltage | (4402)VDC | Float charge voltage |
Charge time | Determined by battery capacity | |
Charge current | 10A | Could be set in the front panel, Max 25A |
Interface |
Alarm silence | Support | |
DC power turn-on | Support | |
Automatically restart | Support | |
alarm |
Battery mode | Beep/4s | |
Battery low/charger fault | Beep/1s | |
UPS fault | Continuously beep | |
Overload | Beep/1s | |
Bypass mode | Beep/2Min | |
Communication |
RS232/ RS485 interface | Support | |
Output dry contactor | Support | |
Intelligent slot | Support | |
Monitor software | Appending with UPS | |
Cooling |
Force air cooling |
Display |
LCD displays UPS status | Support | |
Environment |
Work temperature | 040 | |
Altitude | 1500m | |
Audible noise | 70dB | |
Storage temperature | 1545 | |
Work humidity | 20%95 | |
Standard |
EMS/EMI |
Conducted | IEC EN62040-02 | |
Radiated | |
Anti-interference

Similar Products

Industrial Ups Systems

About our Company

Business Type
Manufacturer
Products
Industrial Ups Systems

Regional Suppliers

Industrial Ups Systems in China

Contact Us

Shenzhen Zhongyuan Chuangda Technology Co., Ltd

Ms. Lisa Zhao

China

Send us a message