Medical ventilator, transport ventilator, emergency ventilator

Business Type
Manufacturer
Country
China
Price

Quick Details

Brand Name: JIUJIUXIN
Model Number: JIXI-H-100A
Place of Origin: China
Minimum Order Quantity: 1
Color: white
Certificate: CE,ISO,SFDA

Product Detail

Use for first aid and ICU,it can be use for pediatric and adult patients
Physical Specifications
Dimensions
Width: 50cm Depth: 50cm
Height: 108cm Weight 25Kg
Packing Dimensions
Width: 58cm Depth: 55cm
Height: 122cm Weight 45Kg
Environmental Specifications
Operating Requirements
Temperature: 5 to 40 ℃;
Relative Humidity: less than 80%;
The atmosphere pressure: 70 to 106 kPa ;
Storage/Shipping Requirements
Temperature: -20 ~ 70℃
Relative Humidity: less than 93%
The atmosphere pressure: 70 to 106 kPa
Electrical Specifications
Input Voltage Requirements
AC Voltage: 220V+/-10%
Frequency: 50HZ+/-2%
Power: 170 VA;
Fuse Specification Information
Quantity: 2
Current Rating: 0.8 A
Voltage Rating: 250 Volts
Type: 5*20 mm RT
Output Voltage Specification Information
AC Voltage: 220V+/-10%,
Frequency: 50HZ+/-2%
Power: 130VA;
Pneumatic Specifications
Oxygen Inlet
Pressurized Oxygen: 0.45 MPa +/-10% medical oxygen.
IEC Classification
Ordinary equipment, not protected against the ingress of liquids
Not protected/Not suitable for use in the presence of flammable
Anesthetic gases.
ClassⅠ, Type B
Performance Specification And Tolerances
Ventilator
Parameters Ranges Remark
Controls
Power ON/OFF
Modes
IPPV (CMV) IPPV+SIGH SIPPV (A/C) SIMV MANUAL BREATH
Tidal Volume 0~1800ml
Breath Rate 5~60 bpm
PEEP 0~2KPa
%O2 45~90%
Sigh
Inspiratory Time 0.5~3sec
Exp. Hold Time 0~1sec
Trigger Level -1~0kpa
Over Pressure Relief ≤6kpa
Alarm Set
Monitors
Tidal Volume 0~2560ml
MIN. Volume 0~99L
Total Breath Rate 0~99 bpm
%O2 0~99%
Main Circuit Pressure -2~10KPa
Performance Specification And Tolerances
Ventilator
Parameters Ranges Tolerances
Alarms and Indicators
High Pressure Alarm Limit 2~6kpa
flash, red indicator +/-0.1kpa
Low Pressure Alarm Limit 0. 2~2kpa
Red indicator +/-0.1kpa
High Minute Volume Alarm Limit 10~30L
flash, Red indicator +/-5%
Low Minute Volume Alarm Limit 1~10L
flash, Red indicator +/-5%
High Rate Alarm Limit 30~59bpm
flash, Red indicator +/-2.5%
Apnea interval 15, 30, 45, 60second flash, Red indicator +/-1second
Alarm Silence 60 sec. max
Power Red indicator
Insp. phase Green indicator
Exp. phase Green indicator
IPPV Mode Green indicator
IPPV+SIGH Green indicator
SIPPV Green indicator
SIMV Green indicator
MANUAL Green indicator
What Is Provided
Parts Number Specification
Ventilator 1
Mobile 1
Humidifier 1
Breath Circuit 1
Manipulators 1
Oxygen Pressure Reducer 1
Mask 1
Hand Book 1
CD For Operation 1
Ms. Doris Chiang

Contact Details

About our Company

Business Type
Manufacturer
Established
Before 2001
Employess
26-100
Annual Revenue
US$25 Million - US$50 Million
Main Markets
North America, Eastern Europe, East Asia, Africa, South America, Southern Europe, South Asia, Oceania, Central America, Western Europe, Middle East
Export Ratio
61% - 70%
Products
Emergency Ventilator, Medical Ventilator, Transport Ventilator